Juniper MX960 Hardware Manual page 466

3d universal edge router
Hide thumbs Also See for MX960:
Table of Contents

Advertisement

MX960 3D Universal Edge Router Hardware Guide
436
Verify the state of fabric planes for all MPCs by issuing the
5.
command.
user@host> show chassis fabric summary
Plane State Uptime
0 Spare 21 seconds
1 Spare 12 seconds
2 Online
12 minutes
3 Online
12 minutes
4 Online
30 minutes
5 Online
30 minutes
Verify the state of MPCs by issuing the
6.
user@host> show chassis fabric fpcs
FPC 1
PFE #0
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #1
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #2
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #3
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
Fabric plane details of all MPCs are similarly displayed.
Verify if any output of the show chassis fabric summary command shows fabric
7.
planes in 'check' state, as it indicates that the fabric plane has an error. You can try
to recover the fabric plane to normal operation by issuing the request chassis fabric
plane <#> offline command, followed by the request chassis fabric plane <#> online
command, where <#> equals the fabric plane in error.
NOTE:
After you issue the request chassis fabric plane <#> offline and
request chassis fabric plane <#> online commands, issue the show
chassis fabric summary command to verify that the fabric plane errors
are rectified and to verify the current state of the fabric planes.
show chassis fabric summary
command.
show chassis fabric fpcs
Copyright © 2017, Juniper Networks, Inc.