Each MX960 high capacity AC power supply has an input mode switch, covered by a
small metal plate. The input mode switch tells the system the number of feeds it should
expect When the input mode switch is set to '0' (zero): expect one feed, an alarm will
be generated if two are providing power. When the input mode swtich is set to '1' (one):
expect two feeds, an alarm will be generated if less than two feeds are active. The
default setting is 1.
In Junos OS Releases 10.1R2 and 10.2R1. there are scenarios in which both the supply
and the system will generate a warning or alarm, and there is at least one scenario
where the supply is OK and the system will still give a warning message. [PR530872]