16 SOFTPLC

The SoftPLC function allows the inverter to assume PLC (Programmable Logical Controller). For further details
regarding the programming of those functions in the CFW100, refer to the CFW100 SoftPLC manual. Below are
described the parameters related to the SoftPLC.
P900 – SoftPLC Status
Adjustable
0 = No App.
Range:
1 = Installing App.
2 = Incompat. App.
3 = App. Stopped
4 = App. Running
Properties:
ro
Description:
It allows the user to view the status in which the SoftPLC is. If there are no applications installed, the parameters
P902 to P959 will not be shown on the HMI.
If this parameter presents option 2 = Incompat. App., it indicates the user's program loaded on the SoftPLC is
not compatible with the CFW100 firmware version.
In this case, it is necessary that the user recompile the project on the WLP, considering the new CFW100 version
and redo the download. If that is not possible, the upload of this application can be done with the WLP, provided
that the application password is known or is not enabled.
P901 – SoftPLC Command
Adjustable
0 = Stop Application
Range:
1 = Run Application
2 = Delete Application
Properties:
cfg
Description:
This parameter allows stopping, running or excluding an application installed, but to do so, the motor must be
disabled.
P902 – Scan Cycle Time
Adjustable
0 to 9.999 s
Range:
Properties:
ro
Description:
This parameter sets the application scanning time. The larger the application, the longer is the scanning time.
P910 to P959 – SoftPLC Parameters
Adjustable
-9999 to 9999
Range:
Properties:
Return
Advance
SoftPLC
Factory
0
Setting:
Factory
0
Setting:
Factory
0
Setting:
Factory
0
Setting:
CFW100 | 16-1