Main Specifications - Konica Minolta cm-5 Instruction Manual

Spectrophotometer
Hide thumbs Also See for cm-5:
Table of Contents

Advertisement

Main Specifications

Model
Reflectance:
Illumination/
viewing
system
Transmittance:
Integrating sphere size ø152 mm
Detector
Spectral separation
device
Wavelength range
Wavelength pitch
Half bandwidth
Measurement range
Light source
Measurement time
Measurement/
Reflectance:
Illumination
area
Transmittance: Approx. ø20 mm/ ø26 mm
Repeatability
Inter-instrument
agreement
Transmittance
chamber
Display
Display languages
White/100%
calibration
Interfaces
Observer
Illuminant
Displayed data
Colorimetric data
Reflectance:
Indexes
Transmittance:
User index
E168
di:8°, de:8° (diffuse illumination: 8° viewing)
SCI (specular component included)/SCE (specular component excluded) switchable
Conforms to CIE No. 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722
condition c standard.
di:0°, de:0° (diffuse illumination: 0° viewing)
Conforms to CIE No. 15, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 condition g
standard.
Dual 40-element silicon photodiode arrays
Planar diffraction grating
360 nm to 740 nm
10 nm
Approx. 10 nm
0 to 175 % (Reflectance or transmittance); Output/display resolution: 0.01%
Pulsed xenon lamp
Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s
Changeable by changing mask and settings.
LAV: ø30 mm/ø36 mm; MAV (optional): ø8 mm/ø11 mm; SAV (optional): ø3 mm/
ø6 mm
Spectral reflectance: Standard deviation within 0.1% (400 nm to 740 nm)
Chromaticity value: Standard deviation within ΔE*ab 0.04
(When a white calibration plate is measured 30 times at 10-second intervals after
white calibration)
Within ΔE*ab 0.15 (Typical) (LAV/SCI)
(Based on 12 BCRA Series II color tiles compared to values measured with a master
body under Konica Minolta standard conditions)
No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm
Sample holders (optional) for holding sheet samples or containers of liquid samples
can be installed/removed
5.7-inch TFT color LCD
English, Japanese, German, French, Italian, Spanish, Simplified Chinese, Portuguese
Automatic white (reflectance)/100% (transmittance) calibration using internal white
calibration plate (Not applicable to 100% calibration when using cells for
transmittance measurements of liquids.)
USB 1.1 (Connection to PC, USB memory
(Connection to serial printer)
2° or 10° Standard Observer
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation
with two light sources possible)
Spectral values/graph (reflectance, transmittance, absorbance), colorimetric values/
graph, color difference values/graph, pass/fail judgment, pseudocolor, color
assessment
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, and color difference in these spaces; Munsell
MI; WI (ASTM E313-73, ASTM E313-96, Hunter); YI (ASTM E313-73, ASTM E313-
96, ASTM D1925); WB (ASTM E313-73); ISO Brightness
Gardner; Iodine Color Number; Platinum-Cobalt Color scale (Hazen/APHA);
European Pharmacopoeia; US Pharmacopeia
User-defined index (Optional Data Management Software SpectraMagic™ NX
required for setting user index.)
Spectrophotometer CM-5
, USB keyboard
*1
); RS-232C standard
*2