Non-stop Adjustment Mode

Non-stop Adjustment Mode allows you to change and adjust the measurement flow without having to stop the
measurement processing during operation.
You use saved image files to adjust measurement flows. You can apply a modified measurement flow while the
Controller is in RUN mode.
Lines 0 and 1 are used simultaneously for the execution of the Non-stop Adjustment Mode.
While the measurement process is executed for line 0, you modify and adjust the measurement flow for line 1.
Typical Application for Non-stop Adjustment Mode
Before operation
Create a setup so that
the NG images are saved.
Select [Transfer data] to
transfer data
on line 0 to line 1.
1
In the Main Window for line 0, select [Transfer data] from the [Function] menu.
The settings for line 0 are transferred to line 1.
Measurement does not stop and continues to be executed on line 0.
2
Click the [Switch Screen] button to display line 1 (Non-stop Adjustment Mode Window).
The display for line 0 changes to the display for line 1. (The main display for line 1 is called the Non-stop
Adjustment Mode Window.) This display change will not stop the measurements on images input to line 0.
3
Click the icon portion of the processing unit to adjust.
To change the flow, use the [Edit flow] tool in the Toolbox Pane.
The settings dialog box for the selected unit is displayed.
4
Modify the processing units.
5
Click [OK].
The settings dialog box closes and the display returns to the Main Window
(layout 1).
If you need to modify the judgement conditions for more than one
processing unit, repeat steps 3 to 4.
At this stage, none of the changes have been applied.
Vision System FH/FZ5 Series
User's Manual (Z340)
During operation
Start the operation
NG results.
Click [Switch Screen] to
switch to the Non-stop
Adjustment Mode.
Re-measure the NG image to
analize the cause of the NG.
WWW.NNC.IR
Adjust the measurement
conditions and judgement
conditions as required.
Perform the re-measurement
with the adjusted conditions
and check if the settings are
properly set.
Select [Non-stop data
transfer] to transfer data
on line 1 to line 0.
Click [Switch Screen]
to exit
the Non-stop Adjustment Mode.
Perform measurements using
the modified conditions.
Setting the Operation Mode