Robbed Bit Setting

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 6# (Trunk)# 6# (0 or 1)#
Description
The Robbed Bit Setting determines if AB or ABCD signaling is used.
AB/ABCD signaling robs bits from the T1 channels, and uses those bits to
transmit signaling information. SF (SuperFrame) normally uses AB
signaling; ESF (Extended SuperFrame) normally uses ABCD signaling.
Programming
Notes
Power-Cycling Requirement. For changes to this parameter to take effect,
the system must be turned off, then back on.
Page 1-194
FF1 8# 4# 6# (1-64)# 6# (0 or 1)#
Trunk Number (1-64)
DBS Manual - Revised April 2000
Section 400-Programming
0=Robbed Bit Off
(AB/ABCD signaling not used)
1=Robbed Bit On
(AB/ABCD signaling is used)