Section 400-Programming
Outgoing Signaling Type
Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 6# (Trunk)# 3# (0-2)#
Description
Determines the signaling class used by T1 channels on outgoing calls
(Immediate Start by default).
Programming
Notes
CO Requirement. The Outgoing Type setting must match what is ordered
from the CO.
Power-Cycling Requirement. For changes to this parameter to take effect,
the system must be turned off, then back on.
DBS-2.3/9.2-400
FF1 8# 4# 6# (1-64)# 3# (0-2)#
Trunk Number (1-64)
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
0=Immediate Start.
1=Wink Start.
2=Dial Tone Start.
Page 1-191