Extension Park Hold Recall Timer; Table 1-16. Extension Park Hold Recall Timer Values - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 1. System Programming (FF1)

Extension Park Hold Recall Timer

Software Version: All Versions
Address: FF1 3# 9# (0-12)#
Description
If an extension parks a trunk call, the parked call will recall (start ringing at
the extension) if it is not picked up. This address determines how long the
parked call remains on hold before it recalls (140 seconds by default).
Programming

Table 1-16. Extension Park Hold Recall Timer values

Related Programming
Attendant Call Reversion Timer for CO Calls: FF1 3# 10# (0-12)#
Notes
Recall Treatment for CO Calls. If a trunk recall is unanswered, it will revert
to the Attendant phone after ringing for the amount of time set in the
Attendant Call Reversion Timer.
Page 1-102
FF1 3# 9# (0-12)#
Extension Park Hold Recall Timer setting
Default: 7 (140 seconds) (see table below)
Setting
0
No recall
1
20 seconds
2
40 seconds
3
60 seconds
4
80 seconds
5
100 seconds
6
120 seconds
7
140 seconds
8
160 seconds
9
180 seconds
10
200 seconds
11
220 seconds
12
240 seconds
DBS Manual - Revised April 2000
Section 400-Programming
Value
DBS-2.3/9.2-400

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents