Network Re-Sync Timer

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 2# 1# (0-25)#
Description
If one clock source fails, the system will switch to another clock source. The
Network Re-Sync Timer determines how many times (once an hour) the
system attempts to return to the original clock source.
For example, if the first clocking (sync) source fails, the system will switch to
the second source, and then will attempt to return to the first source once an
hour for the number of times set in Network Re-Sync Timer. Likewise, if the
system switches to the third source (after the first and second sources fail), the
Network Re-Sync Timer determines how many times the system will attempt
to return to the original clocking source.
Programming
DBS-2.3/9.2-400
FF1 8# 4# 2# 1# (0-25)#
1-24=Number of hours the DBS attempts
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
0=Immediate (DBS attempts to return
to first sync source immediately).
to return to first sync source (once
an hour).
25=No retries (DBS does not attempt
to switch to first sync source).