Digital Pad Settings - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Digital Pad Settings

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 3# (1-12)# (1-12)# (0-30)#
Description
Adjusts the volume of connections made via the T1. Default volume levels
are included for connections between different types of terminals or circuits.
For example, a KTel-to-T1 connection may use one volume setting, while an
SLT-to-T1 connection may use another.
The volume settings are controlled by changing a pad number, which in turn
changes the loss or gain of the connection. In most cases, the default pad
settings do not need to be changed.
If the volume level of a connection is unsatisfactory, include the Receiving
and Sending circuit types in this program, and then adjust the volume by
assigning a new pad number.
Programming
Table 1-47. Digital Pad Settings - circuit types
DBS-2.3/9.2-400
FF1 8# 4# 3# (1-12)# (1-12)# (0-30)#
Circuit Type
Setting
1
K-Tel
2
SLT
3
Data
4
Analog CO Trunk
5
T1 master
6
T1 slave
7
Option 1
8
Option 2
9
DTMF
10
CONF (SCC)
11
Tone 1 (MFR 1)
12
Tone 2 (MFR 2)
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
Receiving
Sending
Circuit Type
Circuit Type
("To" Side)
("From" Side)
(see table below)
Value
Reserved for future use.
Can be used to assign unique
pad levels to circuits that require
special volume levels.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Pad No.
(see table,
next page)
Notes
Page 1-157

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dbs-9.2-400

Table of Contents