Incoming Signaling Type

Software Version: CPC-B Version 4.0 or higher
Address: FF1 8# 4# 6# (Trunk)# 4# (0 or 1)#
Description
Determines the signaling class used by T1 channels on incoming calls
(Immediate Start/Ringdown by default).
Programming
Notes
CO Requirement. The Incoming Type setting must match what is ordered
from the CO.
Power-Cycling Requirement. For changes to this parameter to take effect,
the system must be turned off, then back on.
Page 1-192
FF1 8# 4# 6# (1-64)# 4# (0 or 1)#
Trunk Number (1-64)
DBS Manual - Revised April 2000
Section 400-Programming
0=Immediate Start/
Ringdown.
1=Wink Start.