Station Port Class - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Station Port Class

Software Version: CPC-B Version 4.0 or higher
Address: FF3 (ExtPort)# 37# (1-2 or 7-8)#
Description
This parameter is provided in case a specific phone or group of phones needs
a unique pad level.
By default, DBS extensions are assigned a circuit type based on whether they
are key phones or SLTs. The circuit type is used in the Digital Pad Settings
address (FF1 8# 4# 3#) to determine the loss/gain settings for connections to
the T1 interface.
For example, an SLT is assigned by default as circuit type "2" (see table
below). However, if an SLT in a remote warehouse has inadequate volume
levels, the circuit type for the SLT could be changed to "7". Once the SLT's
circuit type is changed, you can change the pad levels for circuit type "7" to
provide the correct volume setting.
Programming
Table 3-10. Station Port Class - circuit types
DBS-2.3/9.2-400
FF3 (1-144)# 37# (1-2 or 7-8)#
Extension Port
NOTE: This address will allow you to assign circuit types 1-12 to an
extension; however, types 1-2 or 7-8 are the only types that should be
used with extensions.
Setting
1
Key Telephone
2
SLT (2500 set)
7
Option 1 (see "Note" below)
8
Option 2 (see "Note" below)
Circuit types 7-8 are used for assigning unique pad levels to
circuits that require special volume levels. For example, if a
specific analog trunk needs a higher volume level than other
analog trunks, the analog trunk could be defined as an
"Option 1" circuit type.
DBS Manual - Revised April 2000
Chapter 3. Extension Programming (FF3)
Extension Circuit Type
(see table below)
Value
NOTE:
Page 3-43