Section 400-Programming
Yellow Alarm Relay
Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 4# 1# (0 or 1)#
Slave Cabinet:
Description
Determines whether the system closes the alarm relay on the T1 MDF card in
the event of yellow alarms.
The alarm relay can be connected to an external alarm device such as a
buzzer. (This device must be purchased separately; it is not provided with the
DBS T1.)
The Yellow Alarm Detection address (FF1 8# 4# 4/5# 2# 2# 0-15#)
determines how many yellow alarms occur before the relay closes.
Programming
Related Programming
Yellow Alarm Send: FF1 8# 4# (4 or 5)# 1# 7# (0-15)#
Yellow Alarm Detection: FF1 8# 4# (4 or 5)# 2# 2# (0-15)#
Yellow Alarm Recovery: FF1 8# 4# (4 or 5)# 2# 3# (0-15)#
Yellow Alarm Counter: FF1 8# 4# (4 or 5)# 3# 6# (0-15)#
Yellow Alarm FF Key: FF5 (ExtPort)# (Key)# CONF (107# or 127#)#
DBS-2.3/9.2-400
FF1 8# 4# 5# 4# 1# (0 or 1)#
FF1 8# 4# (4 or 5)# 4# 1# (0 or 1)#
4=Master Cabinet
5=Slave Cabinet
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
0=Off (Yellow Alarm relay does not close)
1=On (Yellow Alarm relay closes)
Page 1-183