Slip Counter - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Chapter 1. System Programming (FF1)

Slip Counter

Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 3# 2# (0-9000)#
Slave Cabinet:
Description
Determines how many slips occur before a Slip Alarm FF key is lit. ("Slips"
are losses of data bits due to framing errors.) The FF key lights when the
counter exceeds the specified number within a 24-hour period.
This parameter also determines the number of slips that can occur before the
system switches to the next clock source, at which time the slip error
counter for the first clock source is reset, and all phone calls in progress
are disconnected. It takes 20 seconds for the T1 to reboot.
For instructions on programming T1 alarm keys, see the T1 Reference
Manual (Section 500).
Programming
Related Programming
Sync Source 1: FF1 8# 4# 1# 2# (1-3)#
Sync Source 2: FF1 8# 4# 1# 3# (0-3)#
Sync Source 3: FF1 8# 4# 1# 4# (0-3)#
Slip FF Key: FF5 (ExtPort)# (Key)# CONF (102# or 122#)#
Page 1-178
FF1 8# 4# 5# 3# 2# (0-9000)#
FF1 8# 4# (4 or 5)# 3# 2# (0-9000)#
4=Master Cabinet
5=Slave Cabinet
DBS Manual - Revised April 2000
Section 400-Programming
Number of Slips that must occur
within a 24-hour period before a
Slip Alarm FF key is lit
Default: 9000
DBS-2.3/9.2-400