Red Alarm Counter - Panasonic DBS-2.3-400 Programming Manual

Table of Contents

Advertisement

Section 400-Programming

Red Alarm Counter

Software Version: CPC-B Version 4.0 or higher
Address: Master Cabinet: FF1 8# 4# 4# 3# 3# (0-9000)#
Slave Cabinet:
Description
Determines how many red alarms occur before a Red Alarm FF key is lit.
The FF key lights when the counter exceeds the specified number within a
24-hour period.
For instructions on programming T1 alarm keys, see the T1 Reference
Manual (Section 500).
Programming
Related Programming
Red Alarm Relay: FF1 8# 4# (4 or 5)# 4# 2# (0 or 1)#
Red Alarm Detection: FF1 8# 4# (4 or 5)# 2# 1# (0 or 1)#
Red Alarm FF Key: FF5 (ExtPort)# (Key)# CONF (103# or 123#)#
DBS-2.3/9.2-400
FF1 8# 4# 5# 3# 3# (0-9000)#
FF1 8# 4# (4 or 5)# 3# 3# (0-9000)#
4=Master Cabinet
5=Slave Cabinet
DBS Manual - Revised April 2000
Chapter 1. System Programming (FF1)
Number of Red Alarms that must occur
within a 24-hour period before a
Red Alarm FF key is lit
Default: 9000
Page 1-179