Reset Inline-Power Ports - Extreme Networks ExtremeWare XOS Command Reference Manual

Software version 11.5
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.

reset inline-power ports

reset inline-power ports
reset inline-power ports <port_list>
Description
Power cycles the specified ports.
Syntax Description
portlist
Specifies one or more ports or slots and ports for which power is to be reset.
Default
N/A.
Usage Guidelines
This command power cycles the specified ports. Ports are immediately disabled and then re-enabled,
allowing remote PDs to be power-cycled.
This command affects only inline power; it does not affect network connectivity for the port(s).
Example
The following command resets power for port 4 on slot 3 on a modular switch:
reset inline-power ports 3:4
History
This command was first available in ExtremeWare XOS 11.1.
Platform Availability
This command is available on the G48P and G48Pe modules installed in the BlackDiamond 8800 series
switch and the Summit X450e-24p switch.
533
ExtremeWare XOS 11.5 Command Reference Guide

Advertisement