ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
Power Over Ethernet Commands
show inline-power
show inline-power
Description
Displays inline power status information for the system.
Syntax Description
This command has no arguments or variables.
Default
N/A.
Usage Guidelines
The output indicates the following inline power status information for the system:
Configured inline power status—The status of the inline power for the switch: enabled or disabled.
●
System power surplus—The surplus amount of power on the system, in watts, available for
●
budgeting.
Redundant power surplus—The amount of power on the system, in watts, available for budgeting if
●
one power supply is lost.
System power usage threshold—The configured power usage threshold for each slot, shown as a
●
percentage of budgeted power. Once this threshold has been passed on any slot, the system sends an
SNMP alarm and logs a message.
Disconnect precedence—The method of denying power to PDs if the budgeted power on any slot is
●
exceeded.
Legacy mode—The status of the legacy mode, which allows detection of non-standard PDs.
●
The output indicates the following inline power status information for each slot:
Inline power status—The status of inline power. The status conditions are:
●
Enabled
■
Disabled
■
Firmware status—The operational status of the slot. The status conditions are:
●
Operational
■
Not operational
■
Disabled
■
Subsystem failure
■
Card not present
■
Slot disabled
■
Budgeted power—The amount of power, in watts, that is reserved and available to the slot.
●
Measured power—The amount of power, in watts, that currently being used by the slot.
●
534