ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
Power Over Ethernet Commands

show inline-power

show inline-power
Description
Displays inline power status information for the system.
Syntax Description
This command has no arguments or variables.
Default
N/A.
Usage Guidelines
The output indicates the following inline power status information for the system:
Configured inline power status—The status of the inline power for the switch: enabled or disabled.
System power surplus—The surplus amount of power on the system, in watts, available for
budgeting.
Redundant power surplus—The amount of power on the system, in watts, available for budgeting if
one power supply is lost.
System power usage threshold—The configured power usage threshold for each slot, shown as a
percentage of budgeted power. Once this threshold has been passed on any slot, the system sends an
SNMP alarm and logs a message.
Disconnect precedence—The method of denying power to PDs if the budgeted power on any slot is
exceeded.
Legacy mode—The status of the legacy mode, which allows detection of non-standard PDs.
The output indicates the following inline power status information for each slot:
Inline power status—The status of inline power. The status conditions are:
Enabled
Disabled
Firmware status—The operational status of the slot. The status conditions are:
Operational
Not operational
Disabled
Subsystem failure
Card not present
Slot disabled
Budgeted power—The amount of power, in watts, that is reserved and available to the slot.
Measured power—The amount of power, in watts, that currently being used by the slot.