Disable Slot - Extreme Networks ExtremeWare XOS Command Reference Manual

Software version 11.5
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.

disable slot

disable slot <slot> {offline}
Description
Disables slot and leaves that module in a power down state.
Syntax Description
slot
offline
Default
Enabled.
Usage Guidelines
This command allows the user to disable a slot. When the user types this command, the I/O card in
that particular slot number is brought down, and the slot is powered down. The LEDs on the card go
OFF.
A disabled slot can be re-enabled using the
software on the I/O module is updated to match the software on the primary MSM.
The
command, if invoked after the user disables the slot, shows this slot state as "Power
show slot
Off/Disabled."
If there is no I/O card present in a slot when the user disables the slot, the slot still goes to the
"Disable" state. If a card is inserted in a slot that has been disabled, the card does not come up and
stays in the "Power Off/Disabled" state until the slot is enabled by using the
below.
If you do not save the configuration before you do a switch reboot, the slot will be re-enabled upon
reboot. If you save the configuration after disabling a slot, the slot will remain disabled after a reboot.
On Power over Ethernet (PoE) modules, disabling a slot also disables any inline power that in flowing
to that slot.
BlackDiamond 8800 series switch only. This command applies only to the data, or I/O ports on slots
holding an MSM. The slots holding an MSM on the BlackDiamond 8810 switch are 5 and possibly 6; the
slots holding an MSM on the BlackDiamond 8806 switch are 3 and possibly 4. Use the
parameter to run the diagnostics offline.
ExtremeWare XOS 11.5 Command Reference Guide
Specifies the slot to be disabled.
Specifies that the slot be disabled offline.
NOTE: This variable is supported only on the BlackDiamond 8800 series
switch; that is, those modular switches that support offline diagnostics.
enable slot
command. When the slot is re-enabled, the
enable slot
disable slot
command.
offline
347

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.5

Table of Contents