Configure Bvlan Add Ports Tagged - Extreme Networks ExtremeWare XOS Command Reference Manual

Software version 11.5
Hide thumbs Also See for ExtremeWare XOS:
Table of Contents

Advertisement

ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.

configure bvlan add ports tagged

configure bvlan add ports tagged
configure bvlan <blvan-name> add ports <port_list> tagged
Description
Adds ports to the specified BVLAN.
Syntax Description
bvlan-name
Enter the name of the BVLAN to which you are adding ports.
Default
N/A.
Usage Guidelines
Only tagged ports can be added to the BVLAN.
You cannot configure Connectivity Fault Management (CFM) on ports added to the BVLAN, or apply
ACLs to those ports.
Example
The following command assigns the ports 1:1 to 1:5 to the backbone VLAN (BVLAN) black and tags
those ports:
configure bvlan black add ports 5:1-5 tagged
History
This command was first available in ExtremeWare XOS 11.4.
Platform Availability
This command is available only on the BlackDiamond 10808 and 12804 switch.
723
ExtremeWare XOS 11.5 Command Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware xos 11.5

Table of Contents