ExtremeWare XOS 11.5 supports only the Summit X450 family of switches and the BlackDiamond 8800 series switch.
configure cfm domain ma-level
configure cfm domain <domain_name> ma-level <level>
Description
Changes a previously configured MA level for the specified domain.
Syntax Description
domain_name
level
Default
N/A.
Usage Guidelines
You can have up to 8 domains on a switch, and each one must have a unique MA level. Thus, a given
MA level exists only once one a switch.
The IEEE standard 801.2ag specifies different levels for different network users, as follows:
0 to 2 for end users
●
3 and 4 for Internet service providers (ISPs)
●
5 to 7 for operators (entities carrying the information for the ISPs)
●
Example
The following command changes the MA level of a previously created domain extreme to 2:
configure cfm domain extreme ma-level 2
History
This command was first available in ExtremeWare XOS 11.4.
Platform Availability
This command is available only on the BlackDiamond 10808 and 12804 switches.
ExtremeWare XOS 11.5 Command Reference Guide
Enter the name of the domain for which you want to change the MA level.
Specifies the new MA level you are assigning to this domain. Enter a value
between 0 and 7.
configure cfm domain ma-level
433