Dell PowerConnect M6348 Cli Reference Manual page 350

Command line interface guide
Hide thumbs Also See for PowerConnect M6348:
Table of Contents

Advertisement

hold-multiplier — Multiplier on the transmit interval used to set the TTL in local data
LLDPDUs. (Range: 2–10)
reinit-delay — The delay in seconds before re-initialization. (Range: 1–10 seconds)
Default Configuration
The default transmit interval is 30 seconds.
The default hold-multiplier is 4.
The default delay before re-initialization is 2 seconds.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Examples
The following example displays how to configure LLDP to transmit local information every
1000 seconds.
console(config)#lldp timers interval 1000
The following example displays how to set the timing parameter at 1000 seconds with a hold
multiplier of 8 and a 5 second delay before re-initialization.
console(config)#lldp timers interval 1000 hold 8 reinit 5
lldp transmit
Use the lldp transmit command in Interface Configuration mode to enable the LLDP advertise
(transmit) capability. To disable local data transmission, use the no form of this command.
Syntax
lldp transmit
no lldp transmit
Default Configuration
LLDP is disabled on all supported interfaces.
Command Mode
Interface Configuration (Ethernet) mode
350

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents