Clock Summer-Time Recurring - Dell PowerConnect M6348 Cli Reference Manual

Command line interface guide
Hide thumbs Also See for PowerConnect M6348:
Table of Contents

Advertisement

Default Value
No default setting
User Guidelines
No specific guidelines
Example
console(config)#clock timezone -5 minutes 30 zone IST
no clock timezone
Use the no clock timezone command to reset the time zone settings.
Syntax
no clock timezone
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration
User Guidelines
This command has no specific user guidelines.
Example
console(config)#no clock timezone

clock summer-time recurring

week day month hh:mm week day month
Use the clock summer-time recurring {usa | eu | {
hh:mm
offset
acronym
}} [offset
] [zone
] command to set the summertime offset to UTC
recursively every year. If the optional parameters are not specified, they are read as either '0' or
'\0', as appropriate.
Syntax
week day month hh:mm week day month hh:mm
clock summer-time recurring {usa | eu | {
}}
offset
acronym
[offset
] [zone
]
week — Week of the month. (Range: 1–5, first, last)
934