exec-timeout
Use the exec-timeout command in Line Configuration mode to set the interval that the system
waits for user input before timeout. To restore the default setting, use the no form of this
command.
Syntax
exec-timeout
no exec-timeout
minutes — Integer that specifies the number of minutes. (Range: 0–65535)
seconds — Additional time intervals in seconds. (Range: 0–59)
Default Configuration
The default configuration is 10 minutes.
Command Mode
Line Configuration mode
User Guidelines
To specify no timeout, enter the exec-timeout 0 command.
Example
The following example configures the interval that the system waits until user input is detected
to 20 minutes.
console(config)#line console
console(config-line)#exec-timeout 20
history
Use the history command in Line Configuration mode to enable the command history
function. To disable the command history function, use the no form of this command.
Syntax
history
no history
Default Configuration
The default value for this command is
966
minutes
seconds
[
]
enabled
.