Blinking: The server is in System Lockdown Mode. Activate or unlock the system for operation. See
"Activate or unlock the system" on page
Off: No security feature is enabled on the server.
4 8
System Error LED (yellow)
The system error LED helps you to determine if there are any system errors.
Status
Color
On
Yellow
Off
None
5
Bluetooth LED (blue)
Press the Bluetooth button to enable Bluetooth. After the Bluetooth button is pressed, if SE360 V2 does not
pair with any Bluetooth devices within 10 minutes, Bluetooth will be disabled automatically. Identify the
status of Bluetooth with the Bluetooth LED.
Status
On
Off
6
System ID LED (blue)
Use the system ID button and the blue system ID LED to visually locate the server. Each time you press the
system ID button, the state of the system ID LED changes. The LED can be changed to on, blinking, or off.
You can also use the Lenovo XClarity Controller or a remote management program to change the state of the
system ID LED to assist in visually locating the server among other servers.
7
Power status LED (green)
You can press the power button to power on the server when you finish setting up the server. You also can
hold the power button for several seconds to power off the server if you cannot shut down the server from
the operating system. The states of the power LED are as follows:
Status
Off
Flashing rapidly (four
times per second)
ThinkEdge SE360 V2 User Guide
378
357.
Description
An error has been detected on the server.
Causes might include one or more of the
following errors:
• The temperature of the server reached
the non-critical temperature threshold.
• The voltage of the server reached the
non-critical voltage threshold.
• A fan has been detected to be running at
low speed.
• The power supply has a critical error.
• The power supply is not connected to
the power.
The server is off or the server is on and is
working correctly.
14
Bluetooth button with LED (blue)
Color
Description
Blue
Bluetooth is enabled.
None
Bluetooth is disabled, or the server does not come with Bluetooth.
13
System ID button with system ID LED (blue)
12
Power button with power status LED (green)
Color
Description
None
No power supply is properly installed, or the LED itself has failed.
Green
The server is turned off and is not ready to be turned on. The power button is
disabled. This will last approximately 5 to 10 seconds.
Action
Check the Event log to determine the exact
cause of the error.
None.