3. If applicable, before connecting DC power source to the server, remove the header from the
corresponding power connector.
a. Loosen the two captive screws that secure the header; then, remove the header from the power
connector.
Figure 225. Removing the header
b. Store the header for future use.
Note: Install the header when the power connector is not used. The connector could be damaged
without proper protection.
Install the AC PIB module
Procedure
Step 1.
Insert the PIB module into the slot until it is firmly seated
Step 2.
Secure the PIB module with one screw.
Figure 226. Installing the PIB module
After this task is completed
1. Reinstall the internal power supply unit. See
154.
2. Complete the parts replacement. See
ThinkEdge SE360 V2 User Guide
214
"Install the internal power supply unit (AC PMB)" on page
"Complete the parts replacement" on page
324.