After this task is completed
• Install a new drive or drive filler into the vacant drive bay. See
Note: To make sure that there is adequate system cooling, do not operate the server for more than two
minutes without either a drive or a filler installed in each bay.
• If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Demo Video
Watch the procedure on YouTube
Install a 7mm hot-swap drive
Follow instructions in this section to install a 7mm hot-swap drive.
About this task
Attention:
• Read
"Installation Guidelines" on page 47
work safely.
• Touch the static-protective package that contains the component to any unpainted metal surface on the
server; then, remove it from the package and place it on a static-protective surface.
• To make sure that there is adequate system cooling, do not operate the server for more than two minutes
without either a drive or a filler installed in each bay.
• Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board), drive backplanes, or drive cables, make sure to back up all important data stored in
drives.
• Before you remove any component of a RAID array (drive, RAID card, etc.), back up all RAID configuration
information.
The following notes describe the type of drives that the server supports and other information that you must
consider when you install a drive. For a list of supported drives, see
• Locate the documentation that comes with the drive and follow those instructions in addition to the
instructions in this chapter.
• For a complete list of supported optional devices for the server, see
• Depending on the models, the server supports up to two 7mm 2.5-inch hot-swap SATA/NVMe drives.
• The drive bays are numbered to indicate the installation order (starting from number "0"). Follow the
installation order when you install a drive.
– The upper bay: Bay 0
– The lower bay: Bay 1
Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinkedge/se360v2/7dam/downloads/driver-list/
to see the latest firmware and driver updates for your server.
• Go to
"Update the firmware" on page 350
Procedure
ThinkEdge SE360 V2 User Guide
102
"Install a 7mm hot-swap drive" on page
and
"Safety inspection checklist" on page 48
https://serverproven.lenovo.com
for more information on firmware updating tools.
to ensure that you
https://serverproven.lenovo.com
102.
.
.