Function
Default
HW1 function
1
24-hour clock
Off

Siren options

Table 21 below describes the Siren Options menu.
Table 21: Siren Options menu
Function
Default
Piezo beeps
On
Panel voice
On
Panel piezo
On
alarm
Trouble beeps
On
48
Description
Determines how the HW1 I/O output will function:
Off = no output
1 = interior siren output
2 = output activated when armed
3 = output activated when disarmed
4 = fail to communicate output, activates when fail to
communicate condition occurs (the fail to communicate option
must be on)
5 = alarm output activated when panel is in alarm
Determines whether the panel uses a 24-hour clock (on), or a
12-hour clock (off).
Description
Determines whether the panel piezo produces beeps based
on system activity (on), or is silent (off).
Determines whether the panel announces arming level
changes (on), or not (off).
Determines whether the panel piezo emits alarm sounds (on),
or not (off).
Determines whether the panel and hardwired interior sirens
sound six beeps every minute when a trouble condition
occurs (on), or not (off). The following conditions cause
trouble beeps: AC power failure (when AC power failure
report is on) low CPU battery, sensor failure (supervisory),
sensor trouble (low battery, tamper, etc.), fail to communicate,
restoration of power, no activity timer has timed out (trouble
beeps continue for 5 minutes and if the panel does not see
activity, trouble beeps stop and the panel reports no activity to
the central station).
You can silence trouble beeps by arming or disarming the
system or by pressing the STATUS button. Trouble beeps
resume later if the trouble condition is not cleared.