Vlt Domain - Dell S6100 Configuration Manual

Hide thumbs Also See for S6100:
Table of Contents

Advertisement

Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version
9.8(0.0P5)
9.8(0.0P2)
9.7(0.0)
9.5(0.1)
9.2(0.0)
9.0.2.0
9.0.0.0
8.3.19.0
8.3.8.0
Usage Information
When you create a VLT domain on a switch, the Dell Networking OS automatically assigns a unique unit ID (0 or 1)
to each peer switch. The unit IDs are used for internal system operations. To explicitly configure the unit ID of a VLT
peer, use the unit-id command. Configure a different unit ID (0 or 1) on each peer switch.
This command minimizes the time required for the VLT system to determine the unit ID assigned to each peer
switch when one peer reboots.

vlt domain

Enable VLT on a switch, configure a VLT domain, and enter VLT-Domain Configuration mode.
Syntax
vlt domain domain-id
Parameters
domain-id
Command Modes
CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version
9.8(0.0P5)
9.8(0.0P2)
9.7(0.0)
9.5(0.1)
9.2(0.0)
9.0.2.0
1688
Virtual Link Trunking (VLT)
Description
Introduced on the S4048-ON.
Introduced on the S3048-ON.
Introduced on the S6000-ON.
Introduced on the Z9500.
Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux
(PMUX) mode only.
Introduced on the S6000.
Introduced on the Z9000.
Introduced on the S4820T.
Introduced on the S4810.
Enter the domain ID number. Configure the same domain ID on the peer switch. The
range of domain IDs is from 1 to 1000.
Description
Introduced on the S4048-ON.
Introduced on the S3048-ON.
Introduced on the S6000-ON.
Introduced on the Z9500.
Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux
(PMUX) mode only.
Introduced on the S6000.