Alcatel-Lucent 7450 Configuration Manual page 637

Hide thumbs Also See for 7450:
Table of Contents

Advertisement

version — Specifies the version of the flow data collector.
aggregation
Syntax
[no] aggregation
Context
config>cflowd>collector
Description
This command configures the type of aggregation scheme to be exported.
Specifies the type of data to be aggregated and to the collector.
To configure aggregation, you must decide which type of aggregation scheme to configure:
autonomous system, destination prefix, protocol port, raw, source destination, or source prefix.
This can only be configured if the collector version is configured as V8.
The no form of this command removes all aggregation types from the collector configuration.
Default
no aggregation
as-matrix
Syntax
[no] as-matrix
Context
config>cflowd>collector>aggregation
Description
This command specifies that the aggregation data should be based on autonomous system (AS)
information. An AS matrix contains packet and byte counters for traffic from either source-
destination autonomous systems or last-peer to next-peer autonomous systems.
The no form of this command removes this type of aggregation from the collector configuration.
Default
no as-matrix
destination-prefix
Syntax
[no] destination-prefix
Context
config>cflowd>collector>aggregation
Description
This command specifies that the aggregation data is based on destination prefix information.
The no form removes this type of aggregation from the collector configuration.
Default
none
7450 ESS Router Configuration Guide
Values
Netflow v5, v8, v9, v10 (IPFIX) format
Default
5