bfd-template
Syntax
bfd-template name [create]
no bfd-template name
Context
config>router>bfd
Description
This command creates or edits a BFD template. A BFD template defines the set of configurable
parameters used by a BFD session. These include the transmit and receive timers used for BFD CC
packets, the transmit timer interval used when the session is providing a CV function, the multiplier
value, the echo-receive interval, and whether ther BFD session terminates in the CPM network
processor.
Default
no bfd-template
Parameters
name — Specifies a text string name for the template up to 32 characters in printable 7-bit ASCII,
transmit-interval
Syntax
transmit-interval transmit-interval
no transmit-interval
Context
config>router>bfd>bfd-template
Description
This command specifies the transmit timer used for BFD packets. If the template is used for a BFD
session on an MPLS-TP LSP, then this timer is used for CC packets.
Default
no transmit-interval
Parameters
transmit-interval — Specifies the transmit interval. Note that the minimum interval that can be
receive-interval
Syntax
receive-interval receive-interval
no receive-interval
Context
config>router>bfd>bfd-template
Description
This command specifies the receive timer used for BFD packets. If the template is used for a BFD
session on an MPLS-TP LSP, then this timer is used for CC packets.
Default
no receive-interval
Parameters
receive-interval — Specifies the receive interval. Note that the minimum interval that can be
7450 ESS Router Configuration Guide
enclosed in double quotes.
configured is hardware dependent.
Values
10 ms — 100,000 ms in 1 ms intervals
Default
10 ms for CPM3 or higher; 1 second for other hardware
configured is hardware dependent.
Values
10 ms — 100,000 ms in 1 ms intervals