10.6 Administrator Settings; System Settings-Power Save Settings - Konica Minolta bizhub C360 Service Manual

All-in-one color laser mfp
Hide thumbs Also See for bizhub C360:
Table of Contents

Advertisement

10. UTILITY

10.6 Administrator Settings

• The Administrator Settings will be available by entering the administrator password (8
digits) set by the Administrator Settings or Service Mode.
(The administrator password is initially set to "12345678.")
NOTE
• When the following setting is set to "ON", entering the incorrect administrator
password three times will cause access lock.
The access lock is released after the lapse of a predetermined period of time after
the main power switch is turned OFF and then ON more than 10 seconds later.
The access lock can be released by touching keys as follows.
[Service Mode] → [Enhanced Security] → [Administrator unlocking]
10.6.1

System Settings-Power Save Settings

A. Low Power Mode Settings
(1) Use
• To set the time until low power starts operating after the last key operation has been
completed.
Low power: To turn LED and LCD OFF, and lower the power consumption.
(2) Procedure
• Use the 10-key pad for setting.
• The default setting is 15 min.
B. Sleep Mode Settings
(1) Use
• To set the time until sleep mode starts operating after the last key operation has been
completed.
• Turn all lines OFF except 5 V line for control.
• "OFF" will only be displayed when [Sleep ON/OFF Choice Setting] in Service Mode is
2
set.
NOTE
• The sleep mode will begin in 48 hours even if it sets it to "OFF."
(2) Procedure
• Use the 10-key pad for setting.
• The default setting is 30 min.
C. Power Save Key
(1) Use
• To set the type of the power save mode which starts by pressing the Power Save key.
(2) Procedure
• The default setting is Low Power.
216
2
"15 min." (10 to 240)
"30 min." (15 to 240) / OFF
"Low Power"
Field Service Ver. 2.1 Feb. 2012