5. OTHER MAINTENANCE ITEMS
[2]
[2]
[1]
[2]
9. To reinstall, reverse the order of removal.
10. Perform the following setting. [Service Mode] → [ADF] → [Read Pos Adj]
See P.494
74
[2]
[1]
A0EDF2C087DA
A0EDF2C088DA
[1]
A0EDF2C089DA
Field Service Ver. 2.1 Feb. 2012
5. Move the exposure unit [1] to the
position where the sheets are
removed (where a screwdriver can
reach the screws) in the previous
step.
6. Remove two screws [2], and remove
the exposure unit [1].
7. Remove the harness from the edge
cover [1], and disconnect the con-
nector [2].
8. Remove two screws [1], and remove
the exposure lamp [2] from the expo-
sure unit.