Other Maintenance Items; Disassembly/Adjustment Prohibited Items; Ccd Unit; Ph Unit - Konica Minolta bizhub C360 Service Manual

All-in-one color laser mfp
Hide thumbs Also See for bizhub C360:
Table of Contents

Advertisement

5. OTHER MAINTENANCE ITEMS

5.
OTHER MAINTENANCE ITEMS
5.1

Disassembly/adjustment prohibited items

A. Paint-locked screws
NOTE
• To prevent loose screws, a screw lock in blue or green series color is applied to
the screws.
• The screw lock is applied to the screws that may get loose due to the vibrations
and loads created by the use of machine or due to the vibrations created during
transportation.
• If the screw lock coated screws are loosened or removed, be sure to apply a screw
lock after the screws are tightened.
B. Red-painted screws
NOTE
• The screws which are difficult to be adjusted in the field are painted in red in order
to prevent them from being removed by mistake.
• Do not remove or loosen any of the red-painted screws in the field. It should also
be noted that, when two or more screws are used for a single part, only one repre-
sentative screw may be marked with the red paint.
C. Variable resistors on board
NOTE
• Do not turn the variable resistors on boards for which no adjusting instructions
are given in Adjustment/Setting.
D. Removal of PWBs
CAUTION
• When removing a circuit board or other electrical component, refer to "Handling of
PWBs" and follow the corresponding removal procedures.
• The removal procedures given in the following omit the removal of connectors and
screws securing the circuit board support or circuit board.
• Where it is absolutely necessary to touch the ICs and other electrical components
on the board, be sure to ground your body.
5.1.1

CCD unit

A. Reason for prohibition
• Since the accuracy of the CCD unit is guaranteed as a unit, no accuracy is guaranteed if
it is disassembled.
Therefore, screws that lead to the disassembly of the CCD unit must not be removed.
5.1.2

PH unit

A. Reason for prohibition
• The laser runs inside the PH unit. Opening the cover may cause dust to enter and inter-
rupt the laser. Do no remove any screw which may disassemble the PH unit.
5.1.3

Fusing unit

A. Reason for prohibition
• Inner part of the fusing unit and the position of the fusing belt are adjusted prior to ship-
ping. Do not remove any screw which may disassemble the fusing unit.