5. OTHER MAINTENANCE ITEMS
[1]
[2]
[1]
[3]
124
[1]
[2]
A0EDF2C210DA
A0EDF2C211DA
A0EDF2C212DA
Field Service Ver. 2.1 Feb. 2012
7. Remove the screw [1], and remove
the rail [2] for the developing unit/Y.
8. Remove the screw [1] of the transfer
belt cleaner cooling fan motor assy.
9. Disconnect the connector [1].
10. Remove the harnesses from the
edge cover [2], and remove the
transfer belt cleaner cooling fan
motor assy [3].