Field Service Ver. 2.1 Feb. 2012
23.3.9
Scanner system: distorted image
A. Typical faulty images
B. Troubleshooting procedure
Step
Section
1
Installation
2
2nd/3rd mirrors
carriage
3
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
Check item
Machine is installed on a level sur-
face.
Exposure unit is not properly
aligned with 2nd/3rd mirrors car-
riage.
The problem has been eliminated
through the checks of steps up to 2.
23. IMAGE QUALITY PROBLEM
Result
Action
NO
Reinstall.
YES Perform "Focus positioning of the
scanner and 2nd/3rd mirrors car-
riage" and "Scanner Position
Adjustment."
NO
Change exposure unit.
Change CCD unit.
A02EF4C515DA