Field Service Ver. 2.1 Feb. 2012
26.2 DF-617/SP-501
[12]
[11]
[10]
[9]
[8]
[7]
[1]
Cooling fan (FM1)
[2]
Restriction plate positional volume (VR1)
[3]
Glass cleaning motor (M9)
[4]
Reading roller pressure/retraction motor
(M4)
[5]
Reverse roller pressure/retraction motor
(M5)
[6]
Stamp solenoid (SD3) *
[7]
Lift-up motor (M7)
*: Option
[1]
[13]
[6]
[5]
26. PARTS LAYOUT DRAWING
[2]
[4]
[8]
Exit reverse path switching solenoid (SD2)
[9]
Reading motor (M1)
[10] Registration motor (M2)
[11] Take-up motor (M8)
[12] Exit motor (M3)
[13] Reverse path switching solenoid (SD1)
[3]
A0HUF5C500DA
773