12. SERVICE MODE
12.14.3

Auto Stop Position Adjustment

A. Use
• To automatically adjust the read position for the Sub Scanning Direction.
• To check skew feed.
• When ADF has been replaced.
B. Procedure
(1) Sub Scanning Direction 1-SIde
1. Call the Service Mode to the screen.
2. Touch [ADF] → [Auto Stop Position Adjustment].
3. Touch [Sub Scanning Direction 1-SIde].
4. Place the chart in the document feed tray (with the side having an arrow facing up).
5. Press the Start key.
6. Make sure that result is OK. Then, touch [SET].
7. Touch [END].
8. Touch [Exit] on the Service Mode screen.
9. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON.
NOTE
If the result is Unable:
• Check and correct the skew of the document.
• Manually correct the value of [Original Stop Position].
See P.486
(2) Sub Scanning Direction 2-SIde
1. Call the Service Mode to the screen.
2. Touch [ADF] → [Auto Stop Position Adjustment].
3. Touch [Sub Scanning Direction 2-SIde].
4. Place the chart in the document feed tray (Set the chart with its blank side facing
upward).
5. Press the Start key.
6. Make sure that result is OK. Then, touch [SET].
7. Touch [END].
8. Touch [Exit] on the Service Mode screen.
9. Turn OFF the main power switch, wait for 10 sec., then turn the switch ON.
NOTE
If the result is Unable:
• Check and correct the skew of the document.
• Manually correct the value of [Original Stop Position].
See P.486
488
Field Service Ver. 2.1 Feb. 2012