Manual Bypass Tray Width Adj - Konica Minolta bizhub C360 Service Manual

All-in-one color laser mfp
Hide thumbs Also See for bizhub C360:
Table of Contents

Advertisement

12. SERVICE MODE
(1) Skew adjustment result on the panel
• Skew adjustment result is provided in [Skew Adjust Value], which is selected as follows:
[Service Mode] → [State Confirmation] → [Color Regist].
Skew Adjust Value
Initial
2
End
Move
12.4.20

Manual Bypass Tray Width Adj

2
A. Use
• To set the maximum width and the minimum width for the bypass paper width detection
resistor of the manual bypass guide.
• Use when the bypass paper width detection resistor of the manual bypass guide has
been changed.
• Use when a false paper size is displayed when the manual bypass is used.
B. Procedure
1. Call the Service Mode to the screen.
2. Touch these keys in this order: [Machine] → [Manual Bypass Tray Width Adj].
2
3. Touch [Max. Width].
4. Load the bypass tray with paper having a width of 297 mm.
5. Press the Start key and check that the results are [OK].
6. Touch [Min. Width.].
7. Load the bypass tray with paper having a width of 100 mm.
8. Press the Start key and check that the results are [OK].
✽ Make the adjustment again if the results are [NG].
388
2
• Displays the initial position of the skew correction set in [Skew adjust-
ment] which is selected as follows: [Service Mode] → [Machine] → [Skew
adjustment] → [Print Head Skew Adj.]. The initial position is same as the
one set upon shipment.
• Displays the final skew correction position that was obtained after finish-
ing the image stabilization control.
• Displays how much skew adjust value changed in the previous image
stabilization control.
Field Service Ver. 2.1 Feb. 2012
Description
A0P0F3E546DA