Field Service Ver. 2.1 Feb. 2012
12.9.5
Unit Change
A. Use
• To select who is to replace a unit.
• Upon setup.
• When the unit life arrives, the warning display is intended for the specific person who is
going to replace the unit.
When "User" is selected
When "Service" is selected : Life warning.
• To set whether or not to display a toner near empty warning.
• Developing unit/Y,M,C,K are not subject to this setting because they are replaced by cus-
tomer engineer.
B. Procedure
<Unit Change>
• The following are the default settings:
2
Toner Cartridge
Drum Unit
Waste Toner Box
Punch Dust Box
<Warning Display>
Toner Near Empty : "Yes"
12.9.6
Software Switch Setting
A. Use
• To set the operating characteristic of each function from software switch depending on
what types of printing are normally made.
B. Procedure
1. Touch [Software Switch Setting].
2. Touch [Switch No.] and enter the intended switch number with the ten-key pad.
3. Touch [Bit Assignment].
4. Use [←] or [→] to select a bit. To set the bit, enter 0 or 1 with the ten-key pad.
5. To set the bit in hex, touch [HEX Assignment] and use the ten-key pad and [A] to [F]
keys to enter numbers and characters.
6. Touch [Fix].
12.9.7
Software Switch Setting-Setting items in the software switch setting
A. Change the function version of the machine
2
(1) Use
• To change the function version of the firmware version.
HEX Assignment 10 : Operate with the function version 2.
HEX Assignment 20 : Operate with the function version 3.
(2) Procedure
1. Touch [Software Switch Setting].
2. Touch [Switch No.] and enter "25" with the ten-key pad.
3. Touch [HEX Assignment] and enter "10" or "20" with the ten-key pad.
4. Touch [Fix].
: Printing is inhibited.
Japan
"User"
Service
User
"Service"
User
"Service"
"User"
Service
US, Europe
"User"
Service
User
"Service"
"User"
Service
"User"
Service
No
12. SERVICE MODE
Others1/2/3/4/5
"User"
Service
"User"
Service
"User"
Service
"User"
Service
441
2