19. TROUBLE CODE
19.5.109 C8107: Glass cleaning mechanism trouble
Glass cleaning motor (M9)
Glass cleaning sensor (PS21)
Step
Check the connector between M9-DFCB
1
PJ17 for proper connection and correct as
necessary.
Check the connector between PS21-DFCB
2
PJ17 for proper connection and correct as
necessary.
Check the connector of M9 for proper drive
3
coupling, and correct as necessary.
4
PS21 I/O check, sensor check
5
M9 operation check
6
Change M9
7
Change DFCB
19.5.110 C8302: Cooling fan trouble
Cooling fan (FM1)
Step
Check the connector between FM1-DFCB
1
PJ7 for proper connection and correct as
necessary.
Check the fan for possible overload and
2
correct as necessary.
3
FM1 operation check
4
Change FM1
5
DFCB F7 conduction check
6
Change DFCB
664
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.1 Feb. 2012
DF control board (DFCB)
WIRING DIAGRAM
Control signal
—
—
—
DFCB PJ17-7 (ON)
DFCB PJ17-1 to 4
—
—
DF control board (DFCB)
WIRING DIAGRAM
Control signal
—
—
DFCB PJ7-1 (ON)
—
—
—
Location (Electri-
cal component)
—
—
—
DF-617 I-3
DF-617 I-3
—
—
Location (Electri-
cal component)
—
—
DF-617 B to C-4
—
—
—