4. PERIODICAL MAINTENANCE PROCEDURE
4.6.3
Replacing the transfer belt unit
A. Periodically replacing parts/cycle
• Transfer belt unit : Every 300,000 counts (bizhub C360)
NOTE
• Before replacement operations of the transfer belt unit, make sure to turn OFF the
main power switch and the sub power switch.
B. Removal procedure
1. Remove the rear right cover.
See P.56
[1]
4. Open the right door and regist unit.
[2]
34
Every 260,000 counts (bizhub C280/C220)
[1]
A0EDF2C007DA
[2]
A0EDF2C008DA
[1]
A0EDF2C009DA
Field Service Ver. 2.1 Feb. 2012
2. Disconnect two connectors [1].
3. Remove three screws [1], and
remove right door hinge cover [2].
5. Remove two screws [1] and unlock
the transfer belt [2].