3. OTHER MAINTENANCE ITEM
3.3.10

Exit switch back solenoid (SD2)

1. Remove the rear cover.
See P.17
2. Remove the take-up motor.
See P.31
3. Remove the registration motor.
See P.28
[8]
[7]
[2]
[4] [5]
[6]
[9]
[3]
[2]
[1]
26
[4]
[1]
[3]
[8]
A0P0F2C601DA
[5]
[4]
A0P0F2C602DA
Field Service Ver. 1.0 Jul. 2009
4. Remove two screws [1], and remove
the harness guide [2].
5. Remove the screw [3], and remove
the ground terminal.
6. Disconnect two connectors [4] of the
sensor.
7. Remove the harness from the wire
saddles [5].
8. Remove the E-ring [6] and bushing
[7].
9. Remove four screws [8], and remove
the plate [9].
10. Disconnect the connector [1].
11. Remove the harness from the wire
saddles [2].
12. Remove the screw [3] and spring [4],
and remove the exit switch back
solenoid [5].