Field Service Ver. 2.1 Feb. 2012
12.12.7
Temp. & Humidity
A. Use
• To display the temperature and humidity of a specific location (IDC sensor/fusing unit
portion) inside the machine.
• Used as reference information when a malfunction occurs.
B. Procedure
• Temp-Inside
• Temp-Heater
• Temp-Press.
• Humidity
• Absolute Humidity : 0 to 100 in 1 increments
12.12.8

CCD Check

A. Use
• To display the D/A value of CCD clamp/gain for R, G, and B.
• Used for troubleshooting for the CCD sensor.
B. Procedure
• Use the following guidelines on the correct range of values.
<CCD>
2.1
CLAMP:The maximum value and the minimum value of the output value should be
within the range shown below.
Acceptable clamping rage
GAIN
:The maximum value and the minimum value of the output value should be
within the range shown below.
Acceptable gain range
: 0 to 100 °C in 1 °C increments
: 0 to 260 °C in 1 °C increments
: 0 to 260 °C in 1 °C increments
: 0 to 100 % in 1 % increments
Minimum value
R
600
G
600
B
600
Minimum value
R
20
G
10
B
70
12. SERVICE MODE
Maximum value
1500
1700
1600
Maximum value
238
222
247
475
2.1