D-Link xStack DGS-3620 Series Reference Manual page 631

Layer 3 managed stackable gigabit switch
Hide thumbs Also See for xStack DGS-3620 Series:
Table of Contents

Advertisement

®
xStack
DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch Web UI Reference Guide
External Alarm
swExternalAlarm
swExternalAlarmStacking
DOS Attack
swDoSAttackDetected
Prevention
System
coldStart
warmStart
Power Status
swPowerStatusChg
swPowerFailure
swPowerRecover
Fan Status
swFanFailure
swFanRecover
Temperature
swTemperatureHighAlarm
swTemperatureHighRecover
swTemperatureLowAlarm
swTemperatureLowRecover
DLMS
swDlmsIllegalAc
When external alarm Occurred.
Binding objects:
(1) swExternalAlarmChannel
(2) swExternalAlarmMessage
When external alarm Occurred.
Binding objects:
(1) swExternalAlarmStackingUnit
(2) swExternalAlarmStackingChannel
(3) swExternalAlarmStackingMessage
This trap is sent when the specific DoS packet is
received and trap is enabled.
Binding objects:
(1) swDoSCtrlType
(2) swDoSNotifyVarIpAddr
(3) swDoSNotifyVarPortNumber
A coldStart trap signifies that the SNMPv2
entity, acting in an agent role, is reinitializing
itself and that its configuration may have been
altered.
A warmStart trap signifies that the SNMPv2
entity, acting in an agent role, is reinitializing
itself such that its configuration is unaltered.
Power Status change notification.
Binding objects:
1:swPowerUnitIndex
2:swPowerID
3:swPowerStatus
Power Failure notification.
Binding objects:
1:swPowerUnitIndex
2:swPowerID
3:swPowerStatus
Power Recover notification.
Binding objects:
1:swPowerUnitIndex
2:swPowerID
3:swPowerStatus
Fan Failure notification.
Binding objects:
1:swFanUnitIndex
2:swFanID
Fan Recover notification.
Binding objects:
1:swFanUnitIndex
2:swFanID
Temperature High Alarm notification.
Binding objects:
1:swTemperatureUnitIndex
2:swTemperSensorID
3:swTemperatureCurrent
Temperature High Recover notification.
Binding objects:
1:swTemperatureUnitIndex
2:swTemperSensorID
3:swTemperatureCurrent
Temperature Low Alarm notification.
Binding objects:
1:swTemperatureUnitIndex
2:swTemperSensorID
3:swTemperatureCurrent
Temperature Low Recover notification.
Binding objects:
1:swTemperatureUnitIndex
2:swTemperSensorID
3:swTemperatureCurrent
Generated when the user inputs an illegal
activation code.
Binding objects:
1: swDlmsInstallAc
630
1.3.6.1.4.1.171.12.11.2.2.5
.0.1
1.3.6.1.4.1.171.12.11.2.2.5
.0.2
1.3.6.1.4.1.171.12.59.4.0.1
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.171.12.11.2.2.2
.0.1
1.3.6.1.4.1.171.12.11.2.2.2
.0.2
1.3.6.1.4.1.171.12.11.2.2.2
.0.3
1.3.6.1.4.1.171.12.11.2.2.3
.0.1
1.3.6.1.4.1.171.12.11.2.2.3
.0.2
1,3,6,1,4,1,171,12,11,2,2,4
,0,1.1
1,3,6,1,4,1,171,12,11,2,2,4
,0,2.1
1,3,6,1,4,1,171,12,11,2,2,4
,0,3.1
1,3,6,1,4,1,171,12,11,2,2,4
,0,4.1
1.3.6.1.4.1.171.12.101.0.1