NOTE:
a Clean all paris thoroughly in solvent or carburetor cleaner, and dry with compressed air.
a Blow out all passages.
a Replace valve body as an assembly it any parts are worn or damaged.
a Check all valves tor free movement. lf any fail to slide fre€ly, see Valve Body Repair on page 14-117.
a Coat all parts with ATF before reassembly.
LOCK-UP SHIFT VALVE
LOCK.UP TIMING 8 VALVE
,ar
\,/
SPRING SPECIFICATIONS
CAP
Unit ot length; mm (in)
No.
Spring
Standard {Nsw}
Wile Di8.
o . D .
Flee Length
No. of Coils
o
@
Lock-up shift valve spring
Lock-up timing B valve spring
o . 9 0 ( o . 0 3 5 )
o . 8 0 ( o . 0 3 1 )
7 . 6 0 ( 0 . 2 9 9 )
6 . 6 0 { O . 2 6 0 )
73.70 i.2.9021
6 0 . 8 0 ( 2 . 3 9 4 )
32.O
2 2 . 1
Disassembly/lnspection/Reassembly
14-123