NTFCNCDE Notification Code - Identifies the type of alarm generated by the system
upon occurrence of the event identified by the CONDTYPE. The values are:
– CR Critical alarm
– MJ Major alarm
– MN Minor alarm
SRVEFF Service Effect - Identifies the effect on service caused by the event. The
values are:
– NSA Non service-affecting
– SA Service-affecting
CONDTYPE Condition Type - Specifies the condition type retrieved. The values are:
– AIS Alarm Indication Signal
– LOF Loss of Frame
– LOS Loss of Signal
– MAN Manual (Management) Removal
LOCN Location - Identifies the location where the condition type is monitored. The
values are:
– NEND Near End
– FEND Far End
AIDTYPE - Identifies the type of AID for the notification being retrieved.
Modify BITS-OUT
Select Synchronization -> Bits -> Modify BITS-OUT menu path as shown in
Figure
Figure 3-60 Modify BITS outgoing panel
The Modify BITS OUT panel contains the following fields:
Transmitted ESF - Allows to select the type of the transmitted ESF data-link of the
DS1 signal. The values are Don't Use Actual and Actual. The Default hyperlink
allows to recover the previously existing value or the factory default (Actual).
............................................................................................................................................................................................................................................................
3 - 68
3-60.
Synchronization menu
8DG08136EAAA