Create Blsr; Blsr Panel Parameters; 8Dg08136Eaaa - Alcatel-Lucent 1850 TSS-320 User Provisioning Manual

Transport service switch
Table of Contents

Advertisement

Procedures
............................................................................................................................................................................................................................................................

Create BLSR

Purpose
This procedure allows the operator to create a Protecting or West OCn (OC3, OC12, OC48
and OC192) facility with a Protected or East facility. The UPSR (Unidirectional Path
Switched Ring) facility protection groups can be provisioned on a port-pair basis. For
UPSR, the STS1/STSxC facilities within the OCn that is designated to be the
Protected/WEST facility are designated as the Preferred facilities. The STS1/STSxC
facilities within the OCn that is designated to be the Protecting/EAST facility are
designated as the alternate STS1/STSxC facilities.
........................................................................................................................................................................................................................
1
Select Protection -> BLSR options in the Menu bar.
........................................................................................................................................................................................................................
Clicking on Create the following panel appears:
2
Figure 5-62 BLSR Creation
........................................................................................................................................................................................................................
3
Table 5-22
Parameters.
Table 5-22 BLSR Panel Parameters
Parameter
FFP Access Identifier
............................................................................................................................................................................................................................................................
5 - 94

"BLSR Panel Parameters"

provides the description of BLSR Panel
Description
It is referenced to the protected entity in the FFP (Fast
Facility Protection) group. The protecting entity is
automatically taken as the same port on the next adjacent
module.
Create BLSR

8DG08136EAAA

Issue 3 July 2009