Control Plane - Signalling: Create Network Connection - Alcatel-Lucent 1850 TSS-320 User Provisioning Manual

Transport service switch
Table of Contents

Advertisement

Procedures
............................................................................................................................................................................................................................................................

Control Plane - Signalling: Create Network Connection

Purpose
The procedure allows an operator to establish one Network CONNECTION between two
nodes (source and destination point), as a path component of a Network CALL (call
segment). This connection can go through one or multiple network domains.
In case of a single domain (INNI connection), user can also set source and destination
parameters of the connection (source/destination node and termination point identifiers).
On the other end, where multiple network domains are involved, connection is referred as
E-NNI type and only tunnel profile parameters are required.
This procedure creates an LSP tunnel between source and destination point and uses
extended RSVP-TE protocol for signalling. In the connection set-up, input parameters for
LSP bandwidth and hop list routing are taken from TD-ID/ HOPLIST-ID values. All input
parameters are referenced to OIF-E-NNI-Sig-01.0: Intra-Carrier E-NNI Signaling
Specification (OIF E-NNI 1.0).
........................................................................................................................................................................................................................
Select Control Plane -> CP TDM -> Signalling option in the Menu bar, then in the CP
1
Signaling page click on the Create Network CONNECTION hyperlink or
........................................................................................................................................................................................................................
Expand CTRLPLANE: CP -> TDM CP: CPTDM -> SIGNALING: CPSIG ->
2
CONN: CPCONN options in the Tree area, then in the CP Conn page click on the Create
NETWOK CONNECTION hyperlink. The Create Conn page appears.
............................................................................................................................................................................................................................................................
8DG08136EAAA
Issue 3 July 2009
Control Plane - Signalling: Create Network Connection
5 - 4 1

Hide quick links: