Alcatel-Lucent 1850 TSS-320 User Provisioning Manual page 200

Transport service switch
Table of Contents

Advertisement

Tree area
............................................................................................................................................................................................................................................................
The Rack x > Shelf x-x tab displays the UP Rack-x > Shelf-x and FW/SW Version Data
panel that contains the following parameters.
The UP Rack x Shelf x panel resumes the shelf info and displays the following read-only
fields:
Access Identifier - Specifies the equipment entity.
Current Provisioned Type - Specifies the equipment entity.
Actual Type - Specifies the physically equipped entity type (see Current Provisioned
Type).
Primary/secondary state - Specifies the primary and secondary service state. The
allowable values are the same previously described in
(p.
Shelf ID - Specifies, for the Shelf Types (UNVRL320/UNVRL160), the provisioned
shelf identification value. It can range from 1-31.
Shelf Role - Specifies, for the Shelf Types (UNVRL320/UNVRL160), the
provisioned shelf role. The value can be: MAIN (main shelf of the NE) or NOMAIN
(extension shelf of the NE).
Shelf WDM Role - Specifies, for the Shelf Types (SWTCH, ROADM, UROADM,
ILA and UILA), the provisioned shelf WDM role. The value can be: WDMMASTER
(master shelf of the WDM set of shelves in NE) or WDMSLAVE (slave shelf of the
WDM set of shelves in NE).
The Restart panel resets the specified equipment entity and displays the following fields:
Access Identifier - Specifies the equipment entity.
Phase - Allows to select the type of restart. The values are:
– WARM: Reload of dynamic data only (db in RAM).
– COLD: Reload of dynamic and static data (db and sw). It is supported by MT320,
– POWER-ON: full restart (as if unplugged and plugged), including processor
Command Mode - Allows to select the Command Execution Mode. The values are:
– NORM - Normal, the command is denied if the result of its execution is service-
– FRCD - Forced, the command is completed even if the result of its execution is
The Alarms panel contains the View Hyperlink, on clicking this the list of alarms
associated with the shelf are displayed.
The table contains the following details relevant to the shelf:
Board - Lists all the shelf slots.
............................................................................................................................................................................................................................................................
4 - 22
4-18).
EC320, IOC. It is used with AID = ALL for normal full reset of the NE (cold
restart of EC320 followed by cold restart of MT320).
restart and reloading sw and db. It is supported by MT320. It is used with
AID=ALL for power-on full reset of the NE (cold restart of EC320, power-on
restart of MT320, cold restart of IOCs).
affecting.
service-affecting.
"Access the rack resources"
8DG08136EAAA
Issue 3 July 2009
Overview