– AINS - No condition is sent due to module unplugged
Auto-Provisioning - Specifies the Auto provisioning parameter is used to manage the
Autoprovisioning functionality in case of global (Shelf/NE level) restart: its main
purpose is to prevent the autoprovisioning of a Card (after a restart) in a slot position
in which it has been Logically Deleted. It cannot be provisioned, it is managed only by
the NE but can be retrieved. The choices are:
– ON - Autoprovisioning Allowed in that slot position
– OFF - Autoprovisioning Not-Allowed in that slot position
Command Mode - To change the status of the unit. The choices are:
– NORM (normal)
– FRCD (forced).
Alarm Profile: Specifies the Alarm Severity Assignment profile (ASAP) name to use
with this equipment entity. <userlabel> 1-40 alphanumeric characters (plus '-')
assigned as the userlabel for the desired profile. Click Select hyperlink select a
different profile.
The panel has the following hyperlinks:
Save - Applies the selections and restart with new selection
Remove - Causes the specified equipment to be placed in the out-of-service management
service state.
Remote Inventory - Causes the Remote Inventory window opening for the specified
physical entity (refer to
Alarm panel
This panel contains the View hyperlink that retrieves the current status of any reported
alarm conditions for the specified port and any alarm conditions matching the specified
combination of position-defined input parameters, with the following information:
Raise/Clear Time - Identifies the time when the event is occurred and/or cleared.
AID Access Identifier - Specifies the facility in the <circuit pack acronym>- <rack>-
<shelf>-<slot>-<side> format.
NTFCNCDE Notification Code - Identifies the type of alarm generated by the system
upon occurrence of the event identified by the CONDTYPE. The values are:
– CR Critical alarm
– MJ Major alarm
– MN Minor alarm
SRVEFF Service Effect - Identifies the effect on service caused by the event. The
values are:
– NSA Non service-affecting
– SA Service-affecting
CONDTYPE Condition Type - Specifies the condition type retrieved. The values are:
............................................................................................................................................................................................................................................................
4 - 66